We are a leading Authorized Wholesale Dealer of vlt mcc 101 sine wave filter, vlt aaf 006 advanced active filter and vlt mcc 102 dv dt filter from Chennai, India.

VLT MCC 101 Sine Wave Filter

Request Callback

₹ 150000 / Piece Get Latest Price

Product Brochure
BrandDanfoss
Enclosure Ingress Protection Ratingup to 75 A (500 V) or 45 A (690 V)
Nominal current2.5 - 800 A (500 V)
MountingSide by Side
Range3 x 200 - 500 V,2.5 - 800 A
Maximum switching frequency8 kHz
Minimum switching frequency1.5 kHz - 5 kHz
Overload capacity160% for 60 sec at 10-Minute Intervals
Motor frequencyFor 2.5 - 10 A (500 V)
Voltage rating3 x 200 - 500 V and 3 x 525 - 690 V
Ambient temperature-25 Degree to 45 DegreeC without Derating

Minimum order quantity: 1 Piece

Reduce the motor insulation stress and bearing currents.

VLT Sine-wave Filter MCC 101 output filters are differential-mode low-pass filters that suppress the switching frequency component from the drive and smooth out the phase-to-phase output voltage of the drive to become sinusoidal. This reduces the motor insulation stress and bearing currents.

By supplying the motor with a sinusoidal voltage waveform, the switching acoustic noise from the motor is also eliminated.

VLT AAF 006 Advanced Active Filter

Request Callback

₹ 115000 / Piece Get Latest Price

Product Brochure
Filter functionHigh pass
Filter TypeAdvanced Active Filter
Cutoff freq10 kHz
Order1st order
BrandDanfoss
Mounting TypeSide By Side
FeatureReliable,User Friendly,Energy Saving
CoolingBack-channel air cooling
Ambient temperature45 Degree C
Model numberVLT AAF 006
Voltage range380 - 480 V AC 50 - 60 Hz
Current range190 A,250 A,310 A,400 A
Enclosure degreeIP 21/NEMA Type 1,IP 54/NEMA Type 12
The VLT Advanced Active Filter AAF 006 improves system efficiency and increases grid robustness to avoid downtime. It can compensate for individual drives or it can be installed as a compact standalone solution at a point of common coupling to compensate for several loads simultaneously.

VLT AAF 006 Advanced Active Filter

Request Callback

₹ 200000 / Piece Get Latest Price

Product Brochure
BrandDanfoss
Mounting TypeGround
Thid at:< 7%
Efficiency> 95%
Ambient temperature45 Degree C
CoolingBack-channel air cooling
The VLT Advanced Active Filter AAF 006 improves system efficiency and increases grid robustness to avoid downtime. It can compensate for individual drives or it can be installed as a compact standalone solution at a point of common coupling to compensate for several loads simultaneously.

VLT MCC 102 DV DT Filter

Request Callback

₹ 8000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationPower Distribution
Phase3 - Phase
BrandDanfoss
Model Name/NumberVLT MCC 102
TypedV dt Filter
Output Voltage415 VAC
Input Voltage420 VAC
ControlAutomatic
Voltage Rating3 x 200 - 690 V
Nominal current IN At 50 Hz17 - 880 A @ 200 - 380 V,15 - 780 A at 460 V 12 - 630 A at 600 V and 11 - 630 A at 690 V
Motor frequency0 - 60 Hz without Derating Max. 100 Hz
Ambient temperature-25 Degree to 45 DegreeC
Max. Switching Frequency1,5 kHz - 4 kHz
MountingSide-by-side
Overload capacity160% for 60 sec every 10 min
Compared to sine-wave filters, the dV/dt filters have a cut-off frequency above the switching frequency. The voltage at the motor terminals is still PWM pulse shaped, but the rise time and Upeak are reduced. They are smaller, weigh less and have a lower price compared to sine-wave filters. Furthermore, because of the smaller inductance and capacitance, the dV/dt filters introduce a negligible reactance between inverter and motor and are therefore suitable for high dynamic applications.